Innovative applications for vanadium
flow battery technology
StorEn Tech explores the advantages
of using vanadium redox flow batteries in telecom applications.
Energy storage systems are becoming a requirement
for many electrical power delivery systems. Flow battery technology
has commercial advantages over other energy storage systems because of
the inherent efficiencies and life cycles available that do not exist
with other energy storage technologies.
StorEn is developing a revolutionary suite of products that can:
Economically store and supply large amounts of electricity on demand;
incorporate long life, low maintenance costs; and is scalable from
both a power and storage capacity perspective.
StorEn’s Energy Storage System (ESS), based on a proprietary flow
battery design, is particularly beneficial to renewable energy
providers, power utilities and industrial end users such as telecom
service providers. StorEn’s technology offers these industries the
ability to cost effectively ‘inventory’ electricity on a large scale
and call to service this electrical energy on demand. Unlike other
battery technologies, StorEn’s ESS does not lose capacity after
thousands of charge and discharge cycles.
Description of StorEn’s vanadium flow battery
system
What is a vanadium flow battery? A flow battery is a type of
rechargeable battery in which the energy is stored chemically in
liquid electrolytes. Unlike conventional batteries that store all of
their reactive materials within the cells, a flow battery stores the
electrolyte in tanks. The electrolyte is pumped through the cells and
the electric energy is generated by a chemical reaction that takes
place as the electrolyte passes through the cell stack. The liquid is
then returned into the tanks.
There are two electrolytes, one that is positively charged and one
that is more negatively charged. The technology exploits the natural
ability of vanadium to exist in four different oxidation states. Each
electrolyte tank is charged with vanadium in a different redox couple.
The two electrolytes do not mix together but are separated in the cell
stack by an extremely thin membrane that only allows selected ions to
flow through.
Also in the cells are very stable carbon electrodes, manufactured to a
proprietary process and formulation, where the transfer of chemical
energy to electrical energy takes place. The reactions only involve
the change of state of oxidation of the vanadium pentoxide, and the
electrodes do not change physically or chemically.
Additionally, the presence of vanadium in both electrolyte tanks does
not lead to cross-contamination of the metal species, as it takes
place with any other technology using different metals.
Therefore, a large number of charge and discharge cycles, in excess of
20,000 cycles, may be performed without any significant decrease in
capacity.
Generally, the cells are grouped together in blocks known as stacks
(cell stacks or modules). In each stack the cells are connected
electrically in series by bipolar plates, i.e., conducting plates that
have positive electrolyte on one side and negative on the other.
Therefore, the stack voltage is the sum of the voltage of the
individual cells. A ten-cell stack has ten times the voltage of a
single cell.
Conventional batteries (or cells) may be grouped in series and are
then known as a battery string. The energy of a battery string is
limited by the poorest battery (cell). However, each cell of a flow
battery is practically identical because they share the same
electrolytes. Therefore, flow batteries do not suffer the same
intrinsic limitation.
The stack power (in kW) is also the sum of each cell’s power. The
power of each cell is governed by the battery chemistry, temperature,
and cell dimensions, as well as a few other parameters. However, the
energy (in kWh) of the battery is dictated by the amount of
electrolyte that is present in the tanks. With more electrolyte
(energy) the battery will be able to provide the same amount of power
for longer periods of time. There is practically no upper limit to the
energy to power ratio of a flow battery.
Flow batteries are unique in being able to independently specify the
energy and power to meet the demands of any given application.
Applications that will benefit from StorEn
Technology’s flow battery system include the following:
Telecom applications
StorEn targets on-grid, off-grid, and poor grid situations at
telecommunications sites in North, Central and South America, Europe,
India, Africa, and remote island communities worldwide. For on-grid
applications, StorEn’s ESS can be used in a number of applications
such as traditional battery backup and, at the same time, shift energy
use to a lower time of use rate. In remote locations, StorEn ESS works
well at sites that use a ‘hybrid’ and/or cycling approach where a
diesel generator is combined with renewable energy such as wind and/or
solar to power cellular and microwave sites.
In this market, StorEn’s first to market product offers immediate
benefits such as lower life cycle costs, minimal maintenance and
longer discharge capabilities with end users experiencing short
payback cycles for many systems. The additional environmental benefits
include a significant reduction in diesel emissions and minimal
disposal concerns.
Telecom applications: Traditional backup power
In the majority of telecommunications systems worldwide, lead/acid
batteries are used to provide DC backup functionality or to bridge to
a much longer-running backup system such as a diesel generator. In
grid connected systems, these batteries serve only as a UPS, only
being called into service when the grid fails or there is an outage
due to weather. In North America and other locations, the normal
specifications for backup battery power are to operate up to four
hours continuously on batteries, allowing for continued emergency
communications during the outage. In off-grid telecom sites, diesel
generators provide the primary source of power and batteries are used
as backup if the on-site generator fails to operate.
Lead/acid backup power systems are designed for infrequent use and
generally for shallow depths of discharge due to the fact that the
life span of lead/acid batteries are controlled by the number of
discharge cycles and the depth of discharge during these cycles.
Battery life is also controlled by operating temperatures and by the
charging voltages used during the charge cycle. Recharge times are
often five times that of the discharge cycle, thus making lead/acid
batteries very inefficient to operate in high cyclic locations. Four
hours of discharge can take up to 20 hours to recharge.
For lead/acid batteries, the depth of discharge plays an important
role in determining the operational life of a battery. If an
acceptable depth of discharge is exceeded, the battery system’s life
is severely depleted. A maximum of 30% depth of discharge is
considered acceptable for most telecom designed lead/acid battery
systems. StorEn’s flow battery technology eliminates these issues. The
StorEn flow battery has the ability to cycle between charge and
discharge virtually an unlimited number of times with no ill effect on
the battery. The StorEn-ESS also allows for complete discharge every
time, again, with no ill effect. The third feature is the StorEn flow
battery technology has the ability to rapidly charge and approaches a
one-to-one charge/discharge ratio allowing for quick and rapid
response to multiple power outage scenarios. In locations such as
India, Africa, Central and South America, telecom sites experience
multiple outages each day, stressing the capacities of backup power
systems and requiring continuous replacement of lead/acid battery
systems.
StorEn will be addressing the backup power market for
telecommunications on a worldwide basis. Although telecom service
providers have a number of choices for backup power systems, the value
of replacing lead/acid batteries with StorEn flow battery technology
will enhance a telecom service provider’s network by increasing
reliability, improving longevity of the backup power system and
dramatically improving performance by allowing rapid charge cycling.
Telecom applications: Off-grid prime power and
on-grid poor power sites
Telephone service providers are constantly studying ways to curb the
costs of operating remote telecommunications transmission sites. The
more remote the site, the higher the costs of energy used to power the
site, regardless of whether the energy is utility power or other
sources – such as on-site, diesel-powered generators. Remote
transmission sites are also expensive to service and support. Many
sites are accessible only by helicopter or during the summer months.
There are tens of thousands of transmission sites across the globe,
many of which rely on localised generation of electrical power from
on-site diesel generators. Attempts have been made to augment the
diesel generators with some form of energy storage, such as large
banks of lead/acid batteries. Battery banks have traditionally been
used as backup power systems, operating only when the main source of
power is not available.
Attempts have been made to augment the diesel generators with some
form of energy storage, such as large banks of lead/acid batteries.
Battery banks have traditionally been used as backup power systems
operating only when the main source of power is not available.
There have been attempts to use traditional batteries for cycling down
generators during extended periods of time. In theory, using batteries
could save fuel costs or help eliminate generator noise and pollution
at sites located close to populated areas. Traditional battery
technologies such as lead/acid and lithium batteries cannot hold up to
this aggressive charge and discharge cycling. The cost to constantly
replace damaged batteries becomes more expensive than the realised
operational costs of using batteries in this capacity.
Worldwide, telecommunications service providers have relied on diesel
generators as a primary source of electrical power at remote telecom
sites where utility power is unavailable. Diesel generators provide
primary power to microwave transmission stations located on top of
mountains or on remote islands. The value of the transmitted
information easily justifies the high costs of localised diesel power
generation. These sites are typically referred to as ‘prime power’
sites.
Microwave transmission is used as the backbone of many
telecommunication networks. Microwave systems have proven a reliable
and inexpensive medium to transmit voice and data communications over
long distances or rough terrain such as mountain ranges, between
islands, or locations where cable access is not feasible.
For prime-powered microwave sites, the fuel cost tops the list of
operating expenses. Other expenses, such as engine service and
maintenance, are directly related to engine run hours, load, and
temperature. Generally, the lower the load – as a percentage of engine
rating – the lower the efficiency of the diesel engine, thus the
higher the maintenance costs due to premature engine wear, carbon
build-up, and increased oil change schedules.
Microwave transmission equipment is usually a light load for a diesel
generator. To increase engine efficiency, a ‘dummy load’ in the form
of a resistor bank is added. The energy absorbed by the resistor bank
is completely wasted in the form of heat.
Operational cost savings could be realised if it were possible to
store the excess electrical energy and turn off the generators for a
significant period of time each day. Traditional lead/acid batteries
have been used in an attempt to capture the excess energy from the
generator, turn the generator off and run completely from the
batteries thus turning the site into a ‘cycling power’ site.
Unfortunately, there are issues with this solution.
Traditional lead/acid batteries and lithium batteries are limited to
the number of deep discharge cycles before permanent damage occurs. An
innovative energy storage technology is needed that is not affected by
daily deep discharge cycling and can be quickly charged.
StorEn’s flow battery technology is the forerunning solution for this
application as traditional battery systems fail to perform well when
implemented in off grid sites. StorEn plans to dominate this
application by offering tremendous value to telecom service providers
who operate equipment off-grid. The amount of fuel savings alone
justifies deploying StorEn Flow Battery technology on a large scale.
On-grid energy shifting and UPS
backup using the same platform at telecom sites
Typically, every telecommunications site will
have some form of backup power system. Power is usually supplied by
banks of lead/acid batteries that supply uninterrupted power to the
telecommunications equipment during utility power outages. Most
telecommunications systems operate on DC voltage and use rectification
equipment to convert the AC voltage supplied by the utility into
either 48- or 24-volt DC. Larger sites, such as central office sites,
or Point of Presence (POP) sites also have permanently installed
petroleum generators. The typical load of a central office site is
10-50KW. Backup batteries are typically housed inside a building and
are climate controlled as required. Backup batteries are typically
replaced on a three-to-five-year cycle based on the number of times
they were called into service. There would be many banks of batteries
capable of supplying up to 50KW of power for up to two hours of
runtime.
The StorEn ESS flow battery system could be a
direct replacement for any lead/acid battery bank used in this
capacity. Unlike lead acid batteries, the StorEn ESS system has the
capacity to be fully discharged and recharged many thousands of times
with no detrimental effect on the battery system. The installation of
the StorEn ESS system would improve the reliability of the telecom
network by lengthening the operational runtime of the backup power
system as well as reducing the replacement and disposal costs for lead
acid batteries. The StorEn ESS would also decrease the amount of time
the system would need to recover from an extended outage as the StorEn
ESS charges much more quickly than lead acid batteries.
The StorEn flow battery system can also be
used to shift on-peak utility energy demands to off peak periods on a
daily basis. By controlling the power rectifiers, power delivered to
the telecom transmission equipment can be supplied by the StorEn ESS
during peak load times and the battery can be recharged during off
peak times. This extended use of the StorEn ESS has no detrimental
effect on the battery system thus allowing the telecom service
provider to continue to use the battery in the traditional mode as a
backup power device. The StorEn ESS would be designed to supply up to
six hours of peak load shifting power and an additional two hours of
backup energy power for a total of eight hours of energy storage
capacity.
Telecommunications cell sites, central office
sites, and larger POP (Point of Presence) sites are configured to
operate uninterrupted in the event of voltage dips and power outages.
The load curves of many such sites exhibit flat profiles with
occasional demand spikes due to air conditioner inrush currents.
Based on the Time-of-Use (TOU) tariffs in
place in many states in the US, StorEn’s flow battery technology could
be used to shift the load from the grid to the batteries during the
hours of the day when the utility company is experiencing peak demand.
However, at the same time, the primary purpose of these batteries,
namely, to provide a UPS function, would not be compromised.
Conventional and advanced batteries cannot have the power and storage
duration sized separately from one another. Flow batteries, however,
allow for the independent specification of power and energy. This
feature allows the telecom service provider to specify the amount of
power to be delivered by the battery and, independently, specify the
length of run time used for backup and for the peak shaving
application.
The key here is the flow battery serves two
important roles: It replaces and improves reliability over existing
lead/acid backup batteries used to bridge an outage until the on-site
genset starts, and it reduces utility costs by shifting the utility
energy costs from prime time to night-time tariff rates.
Our vanadium flow battery technology leads the
way in Green House Gas Emissions (GHGs) Emission Reduction and
sustainability.
One StorEn Energy Module 5kW/30kWh coupled to
a photovoltaic system, cycling once per day at 100% Depth of
Discharge, would spare the following GHG emissions:
• 7.7 metric tons of CO2 per annum, or
• 154 metric tons of CO2 over the lifecycle of 25 years¹
All StorEn Energy Modules are fully recyclable
and deliver environmental advantages when compared to alternative
energy storage technologies such as:
• All major components are made of fully recyclable plastic and
metals with a recyclability factor close to 100%;
• Disassembling is very easy as all parts are simply bolted
together;
• The processing is cost-effective for the majority of parts being
primary mechanical reprocessing such as the process used for domestic
appliances;
• The only two components requiring specialist treatments are the
printed circuit board of the battery management system, that are
processed in facilities used for electronic waste such as computers’
motherboards;
• The electrolyte can be processed and reused, or if desired, 100%
of the vanadium can be extracted and reused for other applications
with no impact on primary mining;
• Lack of toxic metals such as lead, cadmium, zinc, and nickel,
which could contaminate the environment;
• Acidity levels are much lesser than lead acid batteries which
again could be a hazard; and
• In its lifespan, one StorEn VFB avoids the disposal, processing,
or landfill of eighty lead-acid batteries of forty lithium-ion
batteries.
References
- Calculator:
www.epa.org
Green Play Ammonia™, Yielder® NFuel Energy.
Spokane, Washington. 99212
509 995 1879
Cell, Pacific Time Zone.
General office:
509-254
6854
4501 East Trent
Ave.
Spokane, WA 99212